About This Item
  • [Specification] - Air Flow In and Out Hole Size: G1/4; Exhaust Hole size: G1/4
  • [NOTE] - 1. Ensure that the thread size of the access hole and muffler hole is correct; 2. If using the corresponding G1/4 thread gauge to detect, there is no problem and can be well matched; if using caliper measurement for reference only, the corresponding thread hole diameter is about 11.5mm.
  • [Application] - It is mainly used for on-off and shunt control of compressed gas in air compressor system, lift, pneumatic can making machine, train horn, pneumatic drilling machine, robot, etc.
  • [How to Use] - Correspond to the thread specification of the trachea joint and muffler joint, wrap a proper amount of sealing tape and tighten
  • [Advantage] - Multi-channel compressed air flow break control, easy to install and use
  • In stock, ready to ship
Cart
Cart
About This Item
  • [Specification] - Air Flow In and Out Hole Size: G1/4; Exhaust Hole size: G1/4
  • [NOTE] - 1. Ensure that the thread size of the access hole and muffler hole is correct; 2. If using the corresponding G1/4 thread gauge to detect, there is no problem and can be well matched; if using caliper measurement for reference only, the corresponding thread hole diameter is about 11.5mm.
  • [Application] - It is mainly used for on-off and shunt control of compressed gas in air compressor system, lift, pneumatic can making machine, train horn, pneumatic drilling machine, robot, etc.
  • [How to Use] - Correspond to the thread specification of the trachea joint and muffler joint, wrap a proper amount of sealing tape and tighten
  • [Advantage] - Multi-channel compressed air flow break control, easy to install and use
Specification

Specification

Inquiry submitted successfully
We will reply within 24 hours during work time. If you haven’t received the reply by then, please check your spam. Thank you!
Product Description:

Features:
1.Multi-channel compressed air flow break control, easy to install and use.
2.It has large flow and simply structure. Easy to maintain and operate.
3.It is mainly used for on-off and shunt control of compressed gas in air compressor system, lift, pneumatic can making machine, train horn, pneumatic drilling machine, robot, etc.

How to Use:
Correspond to the thread specification of the trachea joint and muffler joint, wrap a proper amount of sealing tape and tighten.

NOTE: 
1.Ensure that the thread size of the access hole and muffler hole is correct.
2.Thread size is G1/4, if using the corresponding G1/4 thread gauge to detect, there is no problem and can be well matched; if using caliper measurement for reference only, the corresponding thread hole diameter is about 11.5mm.

Specification:

Model: 3R210-08

Color: Black, Blue

CV values: 0.89

Control Type: Hand return

Valve Type: 3 Port 2 Position

Two Mounting hole Size :4mm / 0.16"

Exhaust Hole size: G 1/4"

Air Flow In and Out Hole Size : G 1/4"

Seal material: Nitrile Rubber

Main parts material: Aluminum alloy

Working pressure: 1.5 - 8 kgf / cm2

Operating temperature: 5~60 Degree Celsius

Total Size : 88 x 35 x 22mm /3.46" x 1.38"x 0.88" (L x W x H)

 

 Package Included:

2 x Hand Pull Valves

Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

Product Variants

Products title ID Price Qty
Products title ID Price Qty
{[item.title]} {[item.id]} {['$' + item.price]}
Qty: {[total.qty]} Item(s)
Total Price: ${[total.price]}
View More

Description

Description

Features:
1.Multi-channel compressed air flow break control, easy to install and use.
2.It has large flow and simply structure. Easy to maintain and operate.
3.It is mainly used for on-off and shunt control of compressed gas in air compressor system, lift, pneumatic can making machine, train horn, pneumatic drilling machine, robot, etc.

How to Use:
Correspond to the thread specification of the trachea joint and muffler joint, wrap a proper amount of sealing tape and tighten.

NOTE: 
1.Ensure that the thread size of the access hole and muffler hole is correct.
2.Thread size is G1/4, if using the corresponding G1/4 thread gauge to detect, there is no problem and can be well matched; if using caliper measurement for reference only, the corresponding thread hole diameter is about 11.5mm.

Specification:

Model: 3R210-08

Color: Black, Blue

CV values: 0.89

Control Type: Hand return

Valve Type: 3 Port 2 Position

Two Mounting hole Size :4mm / 0.16"

Exhaust Hole size: G 1/4"

Air Flow In and Out Hole Size : G 1/4"

Seal material: Nitrile Rubber

Main parts material: Aluminum alloy

Working pressure: 1.5 - 8 kgf / cm2

Operating temperature: 5~60 Degree Celsius

Total Size : 88 x 35 x 22mm /3.46" x 1.38"x 0.88" (L x W x H)

 

 Package Included:

2 x Hand Pull Valves

Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
Show less
Free Shipping to the {[currentShipping.abbr]} over {[currentShipping.price]}
Estimated shipping time will be within {[currentShipping.days]} days
Shipping Method

Ship to

Total Delivery Time = Processing Time + Shipping Time

Free upgraded to UPS over $200

30 Day Free Return
Wholesale Inquiry
* Product Name
* Quantity(Each)
* Email Address
Customer Name
Expected Arrival Time
Customer Note
0/990
If you want to consult the bulk order, you can submit a inquiry or contact us .